Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.882
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Trends Hear ; 28: 23312165241253653, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38715401

RESUMO

This study aimed to preliminarily investigate the associations between performance on the integrated Digit-in-Noise Test (iDIN) and performance on measures of general cognition and working memory (WM). The study recruited 81 older adult hearing aid users between 60 and 95 years of age with bilateral moderate to severe hearing loss. The Chinese version of the Montreal Cognitive Assessment Basic (MoCA-BC) was used to screen older adults for mild cognitive impairment. Speech reception thresholds (SRTs) were measured using 2- to 5-digit sequences of the Mandarin iDIN. The differences in SRT between five-digit and two-digit sequences (SRT5-2), and between five-digit and three-digit sequences (SRT5-3), were used as indicators of memory performance. The results were compared to those from the Digit Span Test and Corsi Blocks Tapping Test, which evaluate WM and attention capacity. SRT5-2 and SRT5-3 demonstrated significant correlations with the three cognitive function tests (rs ranging from -.705 to -.528). Furthermore, SRT5-2 and SRT5-3 were significantly higher in participants who failed the MoCA-BC screening compared to those who passed. The findings show associations between performance on the iDIN and performance on memory tests. However, further validation and exploration are needed to fully establish its effectiveness and efficacy.


Assuntos
Cognição , Disfunção Cognitiva , Auxiliares de Audição , Memória de Curto Prazo , Humanos , Idoso , Feminino , Masculino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Memória de Curto Prazo/fisiologia , Disfunção Cognitiva/diagnóstico , Ruído/efeitos adversos , Percepção da Fala/fisiologia , Teste do Limiar de Recepção da Fala , Fatores Etários , Pessoas com Deficiência Auditiva/psicologia , Pessoas com Deficiência Auditiva/reabilitação , Perda Auditiva/reabilitação , Perda Auditiva/diagnóstico , Perda Auditiva/psicologia , Testes de Estado Mental e Demência , Memória , Estimulação Acústica , Valor Preditivo dos Testes , Correção de Deficiência Auditiva/instrumentação , Limiar Auditivo
2.
JASA Express Lett ; 4(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38727569

RESUMO

Bimodal stimulation, a cochlear implant (CI) in one ear and a hearing aid (HA) in the other, provides highly asymmetrical inputs. To understand how asymmetry affects perception and memory, forward and backward digit spans were measured in nine bimodal listeners. Spans were unchanged from monotic to diotic presentation; there was an average two-digit decrease for dichotic presentation with some extreme cases of decreases to zero spans. Interaurally asymmetrical decreases were not predicted based on the device or better-functioning ear. Therefore, bimodal listeners can demonstrate a strong ear dominance, diminishing memory recall dichotically even when perception was intact monaurally.


Assuntos
Implantes Cocleares , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Feminino , Testes com Listas de Dissílabos , Adulto , Percepção Auditiva/fisiologia , Auxiliares de Audição
4.
Acta Otorhinolaryngol Ital ; 44(2): 113-119, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38651553

RESUMO

Objective: To determine the benefits of binaural hearing rehabilitation in patients with monaural conductive or mixed hearing loss treated with a unilateral bone conduction implant (BCI). Methods: This monocentric study includes 7 patients with monaural conductive or mixed hearing loss who underwent surgical implantation of a unilateral BCI (Bonebridge, Med-El). An ITA Matrix test was performed by each patient included in the study - without and with the BCI and in three different settings - to determine the summation effect, squelch effect and head shadow effect. Subjective hearing benefits were assessed using the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire. Results: The difference in signal to noise ratio of patients without and with BCI was 0.79 dB in the summation setting (p < 0.05), 4.62 dB in the head shadow setting (p < 0.05) and 1.53 dB (p = 0.063) in the squelch setting. The APHAB questionnaire revealed a subjective discomfort in the presence of unexpected sounds in patients using a unilateral BCI (aversiveness score) compared to the same environmental situations without BCI, with a mean discomfort score of 69.00% (SD ± 21.24%) with monaural BCI versus 25.67% (SD ± 16.70%) without BCI (difference: -43.33%, p < 0.05). In terms of global score, patients wearing a unilateral Bonebridge implant did not show any significant differences compared to those without hearing aid (difference: -4.00%, p = 0.310). Conclusions: Our study shows that the use of a unilateral BCI in patients affected by monaural conductive or mixed hearing loss can improve speech perception under noise conditions due to the summation effect and to the decrease of the head shadow effect. However, since monaural BCIs might lead to discomfort under noise conditions in some subjects, a pre-operative assessment of the possible individual benefit of a monaural BCI should be carried out in patients affected by unilateral conductive or mixed hearing loss in order to investigate the possible additional effect of the fitting of hearing aids.


Assuntos
Condução Óssea , Perda Auditiva Condutiva , Perda Auditiva Condutiva-Neurossensorial Mista , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Adulto , Perda Auditiva Condutiva/reabilitação , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva/fisiopatologia , Auxiliares de Audição , Idoso
5.
Cereb Cortex ; 34(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38610087

RESUMO

Hearing is critical to spoken language, cognitive, and social development. Little is known about how early auditory experiences impact the brain structure of children with bilateral sensorineural hearing loss. This study examined the influence of hearing aid use and residual hearing on the auditory cortex of children with severe to profound congenital sensorineural hearing loss. We evaluated cortical preservation in 103 young pediatric cochlear implant candidates (55 females and 48 males) by comparing their multivoxel pattern similarity of auditory cortical structure with that of 78 age-matched children with typical hearing. The results demonstrated that early-stage hearing aid use preserved the auditory cortex of children with bilateral congenital sensorineural hearing loss. Children with less residual hearing experienced a more pronounced advantage from hearing aid use. However, this beneficial effect gradually diminished after 17 months of hearing aid use. These findings support timely fitting of hearing aids in conjunction with early implantation to take advantage of neural preservation to maximize auditory and spoken language development.


Assuntos
Córtex Auditivo , Auxiliares de Audição , Perda Auditiva Neurossensorial , Feminino , Masculino , Humanos , Criança , Perda Auditiva Neurossensorial/terapia , Audição , Encéfalo
6.
Trends Hear ; 28: 23312165241246597, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38629486

RESUMO

Hearing aids and other hearing devices should provide the user with a benefit, for example, compensate for effects of a hearing loss or cancel undesired sounds. However, wearing hearing devices can also have negative effects on perception, previously demonstrated mostly for spatial hearing, sound quality and the perception of the own voice. When hearing devices are set to transparency, that is, provide no gain and resemble open-ear listening as well as possible, these side effects can be studied in isolation. In the present work, we conducted a series of experiments that are concerned with the effect of transparent hearing devices on speech perception in a collocated speech-in-noise task. In such a situation, listening through a hearing device is not expected to have any negative effect, since both speech and noise undergo identical processing, such that the signal-to-noise ratio at ear is not altered and spatial effects are irrelevant. However, we found a consistent hearing device disadvantage for speech intelligibility and similar trends for rated listening effort. Several hypotheses for the possible origin for this disadvantage were tested by including several different devices, gain settings and stimulus levels. While effects of self-noise and nonlinear distortions were ruled out, the exact reason for a hearing device disadvantage on speech perception is still unclear. However, a significant relation to auditory model predictions demonstrate that the speech intelligibility disadvantage is related to sound quality, and is most probably caused by insufficient equalization, artifacts of frequency-dependent signal processing and processing delays.


Assuntos
Auxiliares de Audição , Perda Auditiva , Percepção da Fala , Humanos , Audição , Ruído/efeitos adversos
7.
J Acoust Soc Am ; 155(4): 2460-2469, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38578178

RESUMO

Head-worn devices (HWDs) interfere with the natural transmission of sound from the source to the ears of the listener, worsening their localization abilities. The localization errors introduced by HWDs have been mostly studied in static scenarios, but these errors are reduced if head movements are allowed. We studied the effect of 12 HWDs on an auditory-cued visual search task, where head movements were not restricted. In this task, a visual target had to be identified in a three-dimensional space with the help of an acoustic stimulus emitted from the same location as the visual target. The results showed an increase in the search time caused by the HWDs. Acoustic measurements of a dummy head wearing the studied HWDs showed evidence of impaired localization cues, which were used to estimate the perceived localization errors using computational auditory models of static localization. These models were able to explain the search-time differences in the perceptual task, showing the influence of quadrant errors in the auditory-aided visual search task. These results indicate that HWDs have an impact on sound-source localization even when head movements are possible, which may compromise the safety and the quality of experience of the wearer.


Assuntos
Auxiliares de Audição , Localização de Som , Estimulação Acústica , Movimentos da Cabeça
9.
Int J Pediatr Otorhinolaryngol ; 179: 111930, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38579404

RESUMO

BACKGROUND: Deaf and hard of hearing (DHH) children may experience communication delays, irrespective of early intervention and technology. Australian Sign Language (Auslan) is one approach in early intervention to address language delays. Current prevalence of Auslan use among Australian families with DHH children is unknown. AIMS: The first aim was to determine the proportion of families enrolled in an Australian statewide hearing loss databank who use Auslan with their DHH child. The second aim was to explore the relationships between indicators of child hearing loss (bilateral or unilateral hearing loss, degree of hearing loss, and device use: hearing aids and cochlear implants), family factors (maternal education, attendance at early intervention, family history of deafness, and socio-economic disadvantage) and the family's reported use of Auslan. METHODS: We analysed the enrolment data from 997 families who participated in an Australian statewide hearing loss databank between 2012 and 2021. We described the proportion of families who used Auslan with their DHH child at home. The association between indicators of child hearing loss and family factors, and the parental reports of communication approach were examined using correlation analyses. RESULTS: Eighty-seven of 997 parents (8.7%) reported using Auslan with their DHH child. Of these, 26 (2.6%) used Auslan as their primary language. The use of Auslan at home was associated with the following indicators of child hearing loss: bilateral hearing loss, profound compared to mild hearing loss, and cochlear implant and hearing aid use compared to no device use. The family factors associated with the use of Auslan were: referral or attendance at early intervention compared to those who did not attend, and a family history of deafness compared to those with none. No association was found between maternal education and socio-economic disadvantage and the use of Auslan. CONCLUSION: This Australian study found a low proportion (8.7%) of families with a DHH child who reported using Auslan. Seven child hearing loss and family factors were considered, and five were significantly associated with using Auslan at home. Children with a greater degree of hearing loss, attendance at early intervention and family history of deafness tended to use Auslan.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva , Pessoas com Deficiência Auditiva , Criança , Humanos , Surdez/epidemiologia , Surdez/cirurgia , Surdez/reabilitação , Austrália/epidemiologia , Perda Auditiva/epidemiologia
10.
N Engl J Med ; 390(16): 1505-1512, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38657246
11.
J Am Med Dir Assoc ; 25(5): 853-859, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38643971

RESUMO

OBJECTIVES: Hearing aids have important health benefits for older adults with Alzheimer disease and related dementias (ADRD); however, hearing aid adoption in this group is low. This study aimed to determine where to target hearing aid interventions for American long-term care recipients with ADRD by examining the association of ADRD and residence type with respondent-reported unmet hearing aid need. DESIGN, SETTING, AND PARTICIPANTS: This cross-sectional study used data from the United States National Core Indicators-Aging and Disabilities survey (2015-2019) for long-term care recipients aged ≥65 years. METHODS: We used multivariable logistic regression to model the likelihood of reporting unmet hearing aid need conditional on ADRD status and residence type (own/family house or apartment, residential care, or nursing facility/home), adjusting for sociodemographic factors and response type (self vs proxy). RESULTS: Of the 25,492 respondents [median (IQR) age, 77 (71, 84) years; 7074 (27.8%) male], 5442 (21.4%) had ADRD and 3659 (14.4%) owned hearing aids. Residence types were 17,004 (66.8%) own/family house or apartment, 4966 (19.5%) residential care, and 3522 (13.8%) nursing home. Among non-hearing aid owners, ADRD [adjusted odds ratio (AOR) 0.90, 95% CI 0.80-1.0] and residence type were associated with respondent-reported unmet hearing aid need. Compared to the nursing home reference group, respondents in their own/family home (AOR 1.85, 95% CI 1.61-2.13) and residential care (AOR 1.30, 95% CI 1.10-1.53) were more likely to report unmet hearing aid need. This pattern was significantly more pronounced in people with ADRD than in those without, stemming from an interaction between ADRD and residence type. CONCLUSIONS AND IMPLICATIONS: American long-term care recipients with ADRD living in their own/family home are more likely to report unmet hearing aid need than those with ADRD in institutional and congregate settings. This information can inform the design and delivery of hearing interventions for older adults with ADRD.


Assuntos
Demência , Auxiliares de Audição , Humanos , Auxiliares de Audição/estatística & dados numéricos , Idoso , Masculino , Feminino , Estados Unidos , Estudos Transversais , Idoso de 80 Anos ou mais , Demência/terapia , Perda Auditiva/terapia , Necessidades e Demandas de Serviços de Saúde , Inquéritos e Questionários , Assistência de Longa Duração
12.
Eur Arch Otorhinolaryngol ; 281(6): 2849-2859, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38647685

RESUMO

PURPOSE: The indications of Vibrant Soundbridge (VSB) have been expanded to include patients with conductive and mixed hearing loss due to congenital aural atresia (CAA). However, the current evidence supporting the auditory outcomes of VSB is based mainly on case reports and retrospective chart reviews. Therefore, the present systematic review aims to summarize and critically appraise the current evidence regarding the safety and effectiveness of VSB in children and adult patients with CAA. METHODS: A systematic literature search retrieved studies that evaluated the outcomes of unilateral or bilateral implantation of VSB in patients with CAA. The bibliographic search was conducted in PubMed, Scopus, EBSCO, and Cochrane Central Register of Controlled Trials (CENTRAL) databases from January 2000 to December 2022. RESULTS: Twenty-seven studies were included in the present systematic review. Overall, the speech perception after VSB was good, with a mean word recognition score (WRS) score ranging from 60 to 96.7%. The mean postoperative speech recognition threshold (SRT) after implantation ranged from 20.8 to 50 dB. The effective gain was reported in 15 studies, ranging from 31.3 to 45.5 dB. In terms of user satisfaction with VSB, the included studies showed significant improvements in the patient-reported outcomes, such as the Speech Spatial and Qualities of Hearing scale and Glasgow Hearing Aid Benefit Profile. The VSB implantation was generally safe with low incidence of postoperative complications. CONCLUSION: VSB provides significant benefits to individuals with hearing loss owing to CAA, with very good subjective outcomes and a low risk of complications.


Assuntos
Orelha , Orelha/anormalidades , Humanos , Orelha/cirurgia , Anormalidades Congênitas/cirurgia , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva/congênito , Percepção da Fala , Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia
13.
Trials ; 25(1): 256, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38610038

RESUMO

BACKGROUND: Teleaudiology can potentially improve access to hearing healthcare services. Remote hearing aid fittings offer a new mode of service delivery that removes barriers of geography and access to an audiologist. Real-ear measurements (REMs) are the gold standard for hearing aid output verification but require in-clinic appointments. This study will investigate whether remote hearing aid fittings can provide clinically equivalent outcomes when compared to current, in-clinic, best practice guidelines. RESEARCH DESIGN: A repeated measure, double-blinded crossover design will be used. Participants will be randomly allocated to one of two groups to determine order of intervention, balanced for degree of hearing loss. STUDY SAMPLE: Sixty adults with mild to moderate hearing loss and at least 1 year of experience with hearing aids will be recruited. DATA COLLECTION AND ANALYSIS: Participants will complete two hearing aid fitting protocols, one using an in-clinic fitting process and the other using a remote (at-home) fitting process. In-clinic fittings will include REMs with adjustments to standard (NAL-NL2) prescription targets. The two fitting protocols will then be randomly assigned to participants in a crossover design, so participants and researchers will be blinded to the order of the two fitting protocols. Participants will then have a 4-week period with follow-up appointments for participant-directed gain adjustment. For each fitting protocol, participants will complete objective measurements of final hearing aid output with REMs, speech-in-noise testing, subjective measurements of hearing aid performance, and quality of life measurements. They will then begin an identical period of living with, adjusting, and objective assessment with the other fitting protocol. Data will be analysed as repeated measures with statistical control for potential confounding variables. RESULTS: Data will compare the four-frequency average real-ear aided response (4FREAR) for hearing aids programmed in-clinic and hearing aids programmed remotely, after participant-directed gain adjustments. Secondary measures will assess clinically significant differences in estimated speech intelligibility, hearing-related quality of life, hearing aid benefit, sound quality and preference, and speech-in-noise ability. CONCLUSIONS: This study will inform the development of best practice guidelines for remote hearing aid fittings. If no clinically significant differences are found between in-clinic and remote fit hearing aids, it has the potential to expand teleaudiology initiatives. TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry, ACTRN12623000028606p . Date of registration: 12 January 2023.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Perda Auditiva , Adulto , Humanos , Qualidade de Vida , Austrália , Instituições de Assistência Ambulatorial , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/terapia , Ensaios Clínicos Controlados Aleatórios como Assunto
14.
Trends Hear ; 28: 23312165241246616, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656770

RESUMO

Negativity bias is a cognitive bias that results in negative events being perceptually more salient than positive ones. For hearing care, this means that hearing aid benefits can potentially be overshadowed by adverse experiences. Research has shown that sustaining focus on positive experiences has the potential to mitigate negativity bias. The purpose of the current study was to investigate whether a positive focus (PF) intervention can improve speech-in-noise abilities for experienced hearing aid users. Thirty participants were randomly allocated to a control or PF group (N = 2 × 15). Prior to hearing aid fitting, all participants filled out the short form of the Speech, Spatial and Qualities of Hearing scale (SSQ12) based on their own hearing aids. At the first visit, they were fitted with study hearing aids, and speech-in-noise testing was performed. Both groups then wore the study hearing aids for two weeks and sent daily text messages reporting hours of hearing aid use to an experimenter. In addition, the PF group was instructed to focus on positive listening experiences and to also report them in the daily text messages. After the 2-week trial, all participants filled out the SSQ12 questionnaire based on the study hearing aids and completed the speech-in-noise testing again. Speech-in-noise performance and SSQ12 Qualities score were improved for the PF group but not for the control group. This finding indicates that the PF intervention can improve subjective and objective hearing aid benefits.


Assuntos
Correção de Deficiência Auditiva , Auxiliares de Audição , Ruído , Pessoas com Deficiência Auditiva , Inteligibilidade da Fala , Percepção da Fala , Humanos , Masculino , Feminino , Idoso , Ruído/efeitos adversos , Pessoa de Meia-Idade , Correção de Deficiência Auditiva/instrumentação , Pessoas com Deficiência Auditiva/reabilitação , Pessoas com Deficiência Auditiva/psicologia , Mascaramento Perceptivo , Perda Auditiva/reabilitação , Perda Auditiva/psicologia , Perda Auditiva/diagnóstico , Audiometria da Fala , Inquéritos e Questionários , Idoso de 80 Anos ou mais , Fatores de Tempo , Estimulação Acústica , Audição , Resultado do Tratamento
15.
Med Image Anal ; 94: 103152, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38531210

RESUMO

Today, fitting bespoke hearing aids involves injecting silicone into patients' ears to produce ear canal molds. These are subsequently 3D scanned to create digital ear canal impressions. However, before digital impressions can be used they require a substantial amount of effort in manual 3D editing. In this article, we present computational methods to pre-process ear canal impressions. The aim is to create automation tools to assist the hearing aid design, manufacturing and fitting processes as well as normalizing anatomical data to assist the study of the outer ear canal's morphology. The methods include classifying the handedness of the impression into left and right ear types, orienting the geometries onto the same coordinate system sense, and removing extraneous artifacts introduced by the silicone mold. We investigate the use of convolutional neural networks for performing these semantic tasks and evaluate their accuracy using a dataset of 3000 ear canal impressions. The neural networks proved highly effective at performing these tasks with 95.8% adjusted accuracy in classification, 92.3% within 20° angular error in registration and 93.4% intersection over union in segmentation.


Assuntos
Meato Acústico Externo , Auxiliares de Audição , Humanos , Meato Acústico Externo/anatomia & histologia , Silicones , Redes Neurais de Computação
16.
Int J Pediatr Otorhinolaryngol ; 179: 111925, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38552429

RESUMO

OBJECTIVE: The Baha SoundArc coupling system has been developed as a non-surgical coupling of a Baha sound processor to the skull allowing the transfer of vibrational energy to the cochlear partition via bone conduction pathways. Today, there are several alternatives to this non-surgical approach as the Baha headband/test band, or the Baha Softband, or adhesive patches. Each of these current options have benefits and liabilities. The aim of the study was to evaluate pediatric experience and performance when using two non-surgical options, the Baha SoundArc compared to the Baha Softband. METHODS: Twenty-five children with unilateral mixed or conductive hearing loss aged 5-12 years of age evaluated the use of the Baha SoundArc compared to their existing Baha Softband in a one month take home trial. Participants had a minimum of 3 months experience using the control, Baha Softband. Participants were assessed at baseline and one month following fit of the Baha SoundArc. Measures included an experience and use patient reported outcome, speech perception testing in quiet using Phonetically Balanced Kindergarten (PBK) words, and sound field audiometry. RESULTS: Mean aided soundfield thresholds across the frequency range were 27.6 dB HL for Softband and 26.0 dB HL for SoundArc, which were not significantly different (P = >.05). Mean word recognition score was 80.8% when aided with the Softband device and 85.1% with the SoundArc, which was also not significantly different (P = >.05). Most children favored the aesthetics and usability of the SoundArc over Softband, but comfort ratings were largely similar for both devices. CONCLUSIONS: Bone conduction sound processors mounted on a SoundArc or a Softband resulted in comparable improvements in aided thresholds and speech understanding in children suffering from conductive or mixed hearing loss. Both wearing modalities can be considered equivalent in terms of audiological outcomes, although both patients and clinicians preferred the usability and aesthetics of the SoundArc. The SoundArc provides an alternative wearing option for patients that may otherwise be discouraged by the aesthetics and usability of the Softband device. GOV IDENTIFIER: NCT03333577.


Assuntos
Auxiliares de Audição , Perda Auditiva , Percepção da Fala , Humanos , Criança , Pré-Escolar , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/terapia , Audiometria , Condução Óssea
17.
Trends Hear ; 28: 23312165241227815, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38545698

RESUMO

An objective method for assessing speech audibility is essential to evaluate hearing aid benefit in children who are unable to participate in hearing tests. With consonant-vowel syllables, brainstem-dominant responses elicited at the voice fundamental frequency have proven successful for assessing audibility. This study aimed to harness the neural activity elicited by the slow envelope of the same repetitive consonant-vowel syllables to assess audibility. In adults and children with normal hearing and children with hearing loss wearing hearing aids, neural activity elicited by the stimulus /su∫i/ or /sa∫i/ presented at 55-75 dB SPL was analyzed using the temporal response function approach. No-stimulus runs or very low stimulus level (15 dB SPL) were used to simulate inaudible conditions in adults and children with normal hearing. Both groups of children demonstrated higher response amplitudes relative to adults. Detectability (sensitivity; true positive rate) ranged between 80.1 and 100%, and did not vary by group or stimulus level but varied by stimulus, with /sa∫i/ achieving 100% detectability at 65 dB SPL. The average minimum time needed to detect a response ranged between 3.7 and 6.4 min across stimuli and listener groups, with the shortest times recorded for stimulus /sa∫i/ and in children with hearing loss. Specificity was >94.9%. Responses to the slow envelope of non-meaningful consonant-vowel syllables can be used to ascertain audible vs. inaudible speech with sufficient accuracy within clinically feasible test times. Such responses can increase the clinical usefulness of existing objective approaches to evaluate hearing aid benefit.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Adulto , Criança , Humanos , Fala , Percepção da Fala/fisiologia , Perda Auditiva/diagnóstico , Perda Auditiva Neurossensorial/reabilitação
18.
Am J Public Health ; 114(4): 407-414, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38478867

RESUMO

Objectives. To produce a database of private insurance hearing aid mandates in the United States and quantify the share of privately insured individuals covered by a mandate. Methods. We used health-related policy surveillance methods to create a database of private insurance hearing aid mandates through January 2023. We coded salient features of mandates and combined policy data with American Community Survey and Medicare Expenditure Panel Survey-Insurance Component data to estimate the share of privately insured US residents covered by a mandate from 2008 to 2022. Results. A total of 26 states and 1 territory had private insurance hearing aid mandates. We found variability for mandate exceptions, maximum age eligibility, allowable frequency of benefit use, and coverage amounts. Between 2008 and 2022 the proportion of privately insured youths (aged ≤ 18 years) living where there was a private insurance hearing aid mandate increased from 3.4% to 18.7% and the proportion of privately insured adults (19-64 years) increased from 0.3% to 4.6%. Conclusions. Hearing aid mandates cover a small share of US residents. Mandate exceptions in several states limit coverage, particularly for adults. Public Health Implications. A federal mandate would improve hearing aid access. States can also improve access by adopting exception-free mandates with limited utilization management and no age restrictions. (Am J Public Health. 2024;114(4):407-414. https://doi.org/10.2105/AJPH.2023.307551).


Assuntos
Auxiliares de Audição , Cobertura do Seguro , Adulto , Adolescente , Humanos , Estados Unidos , Idoso , Epidemiologia Legal , Medicare , Política de Saúde , Seguro Saúde
20.
Sensors (Basel) ; 24(5)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38475083

RESUMO

This paper provides a review of various machine learning approaches that have appeared in the literature aimed at individualizing or personalizing the amplification settings of hearing aids. After stating the limitations associated with the current one-size-fits-all settings of hearing aid prescriptions, a spectrum of studies in engineering and hearing science are discussed. These studies involve making adjustments to prescriptive values in order to enable preferred and individualized settings for a hearing aid user in an audio environment of interest to that user. This review gathers, in one place, a comprehensive collection of works that have been conducted thus far with respect to achieving the personalization or individualization of the amplification function of hearing aids. Furthermore, it underscores the impact that machine learning can have on enabling an improved and personalized hearing experience for hearing aid users. This paper concludes by stating the challenges and future research directions in this area.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Humanos , Perda Auditiva Neurossensorial/reabilitação , Aprendizado de Máquina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA